Model | OTM-TDW60-12V | OTM-TDW60-24V | OTM-TDW60-36V | OTM-TDW60-48V | ||
output | DC Voltage | 12V | 24V | 36V | 48V | |
Voltage Tolerance | ±0.5V | |||||
Rated current | 5A | 2.5A | 1.66A | 1.25A | ||
Rated power | 60W | |||||
input | Voltage Range | 180~250VAC (or 90~130VAC) | ||||
Frequency Range | 47~63HZ | |||||
Power Factor (Typ.) | PF≧0.95 | |||||
Efficiency(Typ.) | 83% | 86% | 87% | 88% | ||
AC Current(Typ.) | 0.35A | 0.34A | 0.33A | 0.33A | ||
Leakage current | ﹤0.70mA/220VAC | |||||
Protection | Short Circuit | Hiccup mode, recovers automatically after fault condition is removed | ||||
Over Loading | ≦120% | |||||
Over temperature | 100℃±10℃ (The output voltage will turn off when the temperature is higher then100℃±10℃, after the temperature drop off ,it will recovery) automatic | |||||
Environment | Working TEMP. | -40~+60℃ | ||||
Working Humidity | 20~90%RH, non-condensing | |||||
Storage TEM.,Humidity | -40~+80℃,10~95%RH | |||||
TEMP.coefficient | ±0.03%/℃(0~50℃) | |||||
Vibration | 10~500Hz,2G 10min./1 cycle,period for 60min. each along X,Y,Z axes | |||||
Safety&EMC | Safety standards | EN61347-1 EN61347-2-13 | ||||
Withstand voltage | I/P-O/P:3.75KVAC | |||||
Isolation resistance | I/P-O/P:100MΩ/500VDC/25℃/70%RH | |||||
EMC EMISSION | EN55015,EN61000-3-2,3 (≧50%loading) | |||||
EMC IMMUNITY | EN61000-4-2,3,4,5,6,11(Surge 4KV) | |||||
Others | Net.Weight | 1.1 Kg | ||||
Size | 200*70*46mm(L*W*H) | |||||
packing | 329*279*176 10PCS | |||||
Notes | 1. All parameters if NOT specially mentioned are measured at 220VAC input, rated load and 25℃ of ambient temperature. | |||||
2. To extend the driver’s using life ,please reduce the loading when start the drivers at lower input voltage. | ||||||
3.Loading should be 60-100% |
1.universal AC input
2.Protections: short circuit, over load, over temp, over voltage
3.Build-in EMI filter with tiny ripple
4.100%full load burn-in test
5.Small volume high-efficiency
6.Conform to EN60950 GB4943 UL60950 safety standards
7.Conform to GB9254, EN55022,EMC standards